The Blue Sea Systems ST Blade Split Bus Fuse Block with Ground is for use when a mix of switched and 24-hour circuits are desired in the same block. This fuse block provides two isolated groups of six ATO/ATC circuits. Use this fuse block with either two isolated batteries or with a single battery providing a mix of 24 hour and switched circuits. Screw terminals for securing wires accept ring terminals. One-piece stainless flange nuts ensure safe and secure connections. Clear insulating cover has label recesses and storage for two fuses and satisfies ABYC/USCG insulation requirements. Easy-to-open, push-button latch for access to fuses. Tin-plated copper buses and fuse clips. Fuses sold separately.
• Circuits: 12
• Maximum Amperage: 100A per block / 30A per circuit
• Maximum Voltage: 32V DC
• Mounting: #8 Screw (M4)
• Negative Bus: #10-32 Stud
• Positive Bus: #10-32 Stud
• Recommended Torque: 24 in.-lb. (2.71 Nm)
• Screw Terminal Torque: 15 in.-lb. (1.69 Nm)
• Screw Terminal Type: #8-32 screws with captive star lock washer
• 7.35"L x 3.32"W x 1.52"H w/cover
Blue Sea Systems No. 5032
Show moreShow less
• Circuits: 12
• Maximum Amperage: 100A per block / 30A per circuit
• Maximum Voltage: 32V DC
• Mounting: #8 Screw (M4)
• Negative Bus: #10-32 Stud
• Positive Bus: #10-32 Stud
• Recommended Torque: 24 in.-lb. (2.71 Nm)
• Screw Terminal Torque: 15 in.-lb. (1.69 Nm)
• Screw Terminal Type: #8-32 screws with captive star lock washer
• 7.35"L x 3.32"W x 1.52"H w/cover
Blue Sea Systems No. 5032
- Two isolated groups of 6 ATO/ATC circuits
- Great for a mix of switched and 24-hr. circuits
- Screw terminals accept ring terminals
- Clear insulating cover w/label recesses
- Tin-plated copper buses and fuse clips
Specs
Unit Weight | 0.90 lb |
---|---|
Brand | Blue Sea Systems |

WARNING: Cancer and Reproductive Harm
For more information, go to www.P65Warnings.ca.gov/product.
Reviews
Q & A
The Blue Sea Systems ST Blade Split Bus Fuse Block with Ground is for use when a mix of switched and 24-hour circuits are desired in the same block. This fuse block provides two isolated groups of six ATO/ATC circuits. Use this fuse block with either two isolated batteries or with a single battery providing a mix of 24 hour and switched circuits. Screw terminals for securing wires accept ring terminals. One-piece stainless flange nuts ensure safe and secure connections. Clear insulating cover has label recesses and storage for two fuses and satisfies ABYC/USCG insulation requirements. Easy-to-open, push-button latch for access to fuses. Tin-plated copper buses and fuse clips. Fuses sold separately.
• Circuits: 12
• Maximum Amperage: 100A per block / 30A per circuit
• Maximum Voltage: 32V DC
• Mounting: #8 Screw (M4)
• Negative Bus: #10-32 Stud
• Positive Bus: #10-32 Stud
• Recommended Torque: 24 in.-lb. (2.71 Nm)
• Screw Terminal Torque: 15 in.-lb. (1.69 Nm)
• Screw Terminal Type: #8-32 screws with captive star lock washer
• 7.35"L x 3.32"W x 1.52"H w/cover
Blue Sea Systems No. 5032
Show moreShow less
• Circuits: 12
• Maximum Amperage: 100A per block / 30A per circuit
• Maximum Voltage: 32V DC
• Mounting: #8 Screw (M4)
• Negative Bus: #10-32 Stud
• Positive Bus: #10-32 Stud
• Recommended Torque: 24 in.-lb. (2.71 Nm)
• Screw Terminal Torque: 15 in.-lb. (1.69 Nm)
• Screw Terminal Type: #8-32 screws with captive star lock washer
• 7.35"L x 3.32"W x 1.52"H w/cover
Blue Sea Systems No. 5032
- Two isolated groups of 6 ATO/ATC circuits
- Great for a mix of switched and 24-hr. circuits
- Screw terminals accept ring terminals
- Clear insulating cover w/label recesses
- Tin-plated copper buses and fuse clips
Unit Weight | 0.90 lb |
---|---|